StadiumDesigner
Guide

How long does it take to empty a stadium?

By MakeHelm Ltd · Updated

A UK football ground is designed so that every spectator can get from their seat to the start of the exit system within eight minutes under normal conditions. Exits are sized from that time and a flow rate of 66 people per metre of width per minute on stairs and gangways, or 82 on the level.

That eight-minute figure, from the Guide to Safety at Sports Grounds (the "Green Guide"), is one of the numbers that decides how many people a stand may hold. It is also why a stadium's capacity can be cut if its exits are too narrow, however many seats it has.

The eight-minute rule

The Green Guide splits a ground into zones. The one that matters for exits is the journey from the viewing area to the start of the exit system: usually the top of a vomitory (the tunnel through the stand) or a stair at the back of a tier. The Guide calls this the Zone 2 travel time and, for calculation purposes, sets it at a maximum of eight minutes under normal conditions.

Eight minutes is not how long it takes to get from your seat to your car. It is the time allowed for everyone in a section to reach the exit system, which is then designed to carry that flow away without queues building up. The aim is to keep people moving steadily rather than bunching on stairs and gangways.

Emergencies are shorter

For an emergency evacuation the time depends on the fire risk of the route. The SGSA's worked example uses eight minutes for a low-risk concourse and two and a half minutes for a route through higher-risk areas such as a hospitality lounge. Less time means the same crowd needs wider or more exits.

Flow rates: how many people get through a metre

The second number is the rate of passage. The Green Guide's maximum is 66 people per metre of exit width per minute on a stepped surface and 82 on a level one. Stairs are slower because people watch their feet. Ground managers can choose lower rates if the route is awkward, poorly lit or badly managed.

Put the two together and you get exit capacity:

exit capacity = width (m) × time (min) × flow rate

The SGSA's worked example for a football stand has four vomitories, each 1.5 m wide, leading to four 3 m exit gates. The calculation uses the narrowest point, the vomitories, so the main tier's exit capacity is 4 × 1.5 × 8 × 66 = 3,168 people. However many seats that tier has, its exits only support 3,168 people, and a ground's safe capacity is set by the tightest of these calculations.

A worked example in Stadium Designer

The game uses the same idea with one simplification: every fan leaves through the ground's exit gates, each 2.4 m wide, at the stepped rate of 66 people per metre per minute. Time to empty is capacity divided by total gate width times flow. Here is Harbour Park:

  1. Capacity: 25,087
  2. Exit width: 26 gates × 2.4 m = 62.4 m
  3. Flow: 62.4 m × 66 = 4,118 people a minute
  4. Time to empty: 25,087 ÷ 4,118 = 6m 05s, inside the 8-minute limit

Turn it round to size the gates. One 2.4 m gate clears 1,267 people in 8 minutes, so 25,087 fans need at least 20 gates. Harbour Park has 26, which leaves room to add seats before the exits become the limit.

All five presets, worked out the same way:

The editor's status bar turns amber once a design takes more than 8 minutes to empty and red once it takes a quarter longer than that. The fix is usually more gates: each one costs £120,000 in the game, about the price of 32 standard seats.

3D view of Harbour Park, a Stadium Designer preset ground
Harbour Park at night: 25,087 fans, 26 gates and an empty ground in 6m 05s.

Kiosks and toilets: the half-time queue

Getting out is a safety question; getting a pie at half-time is a comfort one, but fans notice it more. Real-world provision depends on the crowd, the ground and the licence. UEFA's stadium regulations give the clearest published ratios for toilets: assuming 80% of the crowd is male, one toilet and one sink per 250 men plus one urinal per 125 men, and for women one toilet per 120 in the home sections and one per 80 in the away end.

Stadium Designer boils this down to two rules of thumb:

  • One kiosk per 300 fans. Above that, half-time queues grow and the matchday score suffers.
  • One toilet per 70 fans. A single blended figure for every kind of toilet, deliberately on the generous side.

Harbour Park runs at one kiosk per 348 fans and one toilet per 70, which is why its matchday verdict reads: "Loud and tight to the pitch, but bring a flask: the kiosks can't keep up at half-time."

In Stadium Designer

In the editor, the Access panel sets the number of gates, the Concourse panel sets kiosks and toilets, and the status bar shows exit time and both ratios live. Add a tier and watch the exit time climb; add gates until it turns green again.

The Championship Ground challenge makes this the main event: grow Elmfield Road into a 25,000-seat home for an ambitious second-tier club. Its goals are 25,000+ seats, empties in ≤ 8 min and kiosks ≤ 1:300, so every new seat needs a share of a gate and a kiosk to go with it. For the sightline side of a bigger ground, see stadium sightlines and the C-value.

Try it

Open Elmfield Road in the editor, or take the Championship Ground challenge: Grow Elmfield Road into a 25,000-seat home for an ambitious second-tier club.

Frequently asked questions

How long does it take to empty a football stadium?

UK grounds are designed so that spectators can get from their seats to the start of the exit system within eight minutes under normal conditions. That figure sets the width of the gangways, vomitories and exits. In an emergency the time allowed ranges from two and a half minutes where there is a high fire risk up to eight minutes where the risk is low. Clearing the concourses, turnstiles and nearby streets takes longer.

What is the eight-minute rule for stadiums?

The Guide to Safety at Sports Grounds sets a maximum of eight minutes, under normal conditions, for spectators to travel from the viewing area to the start of the exit system. Designers multiply that time by the width of the exits and a flow rate to work out how many people a stand can safely hold.

How many people can go through a stadium exit per minute?

The Green Guide's maximum flow rates are 66 people per metre of width per minute on stepped surfaces such as gangways and stairs, and 82 per metre per minute on level surfaces. A 1.5 m vomitory on a stepped route therefore lets about 99 people a minute through.

How many toilets does a football stadium need?

UEFA's stadium regulations, assuming a crowd that is 80% male, ask for one toilet and one sink per 250 men plus one urinal per 125 men, and for women one toilet per 120 in home sections and one per 80 in the away end. Stadium Designer simplifies this to one toilet per 70 fans.

How many gates does a 25,087-capacity ground need in Stadium Designer?

Each 2.4 m gate lets out 66 people per metre per minute, so it clears 1,267 people in 8 minutes. Harbour Park would need at least 20 gates to empty in time; it has 26, so it empties in 6m 05s.

Sources

  1. Guide to Safety at Sports Grounds, Worked Example A: Football/Rugby (PDF) (SGSA: eight-minute Zone 2 travel time, exit capacity calculations)
  2. Egress (SGSA: flow rates of 66 and 82 per metre per minute)
  3. Guide to Safety at Sports Grounds (the Green Guide) (Sports Grounds Safety Authority, sixth edition)
  4. Stadium Infrastructure Regulations, Article 19: Sanitary facilities for spectators (UEFA: toilet ratios)

Rules of thumb for a design game, not engineering or safety advice. Stadium Designer's numbers come from a simplified model; real grounds are designed by qualified engineers to the Guide to Safety at Sports Grounds and local licensing conditions.